5.4.2 MXWare Program Operation
For instructions about operating the MXWare program, click on the About/Help menu when running the
MXWare program.
5.5 Linking MX8750s
To link two or more MX8750s together, complete the following steps prior to turning the MX8750s on.
1. Set the DATA SELECT switch to Multi-Unit Master on the MX8750 that will be connected to the
computer.
2. Set the DATA SELECT switch to Normal on all other units.
3. Connect a standard 5 pin MIDI cable from the Master unit Midi Out to the Midi In on the second unit.
4. Connect additional midi cables from the Midi Out to Midi In connectors on any additional units.
5. On the last MX8750 connect a MIDI cable from its MIDI Out to the MIDI In on the Multi-Unit Master
MX8750.
6. Set the DEVICE ID dip switches on the MX8750s as shown in the table below. The Device ID will
be the number of the processor in the MXWare program.
Device ID Settings
Page 8